The New York City Department of Buildings has approved the Independence® Series boiler:

Approval No. MEA 154-93-E Vol. III.
The City of New York requires a Licensed Master Plumber supervise the installation of this product.
The Massachusetts Board of Plumbers and Gas Fitters has approved the Independence® Series boiler. See the Massachusetts

Board of Plumbers and Gas Fitters website, http://license.reg.state.ma.us/pubLic/pb_pre_form.asp for the latest Approval

Code or ask your local Sales Representative.
The Commonwealth of Massachusetts requires this product to be installed by a Licensed Plumber or Gas Fitter.

The following terms are used throughout this manual to bring attention to the presence of hazards of various risk

levels, or to important information concerning product life.

DANGER

Indicates an imminently hazardous situation

which, if not avoided, will result in death, serious

injury or substantial property damage.

CAUTION

Indicates a potentially hazardous situation which,

if not avoided, may result in moderate or minor

injury or property damage.

WARNING

Indicates a potentially hazardous situation which,

if not avoided, could result in death, serious injury

or substantial property damage.

NOTICE

Indicates special instructions on installation,

operation, or maintenance which are important

but not related to personal injury hazards.

CAUTION

If, during normal operation, it is necessary to add water to this boiler more frequently than once a month,

consult a qualified service technician to check your system for leaks. A leaky system will increase the volume

of make-up water supplied to the boiler which can significantly shorten the life of the boiler. Entrained in

make-up water are dissolved minerals and oxygen. When the fresh, cool make-up water is heated in the boiler

the minerals fall out as sediment and the oxygen escapes as a gas. Both can result in reduced boiler life. The

accumulation of sediment can eventually isolate the water from contacting the cast iron. When this happens

the cast iron in that area gets extremely hot and may eventually crack. The presence of free oxygen in the

boiler creates a corrosive atmosphere which, if the concentration becomes high enough, can corrode the cast

iron through from the inside. Since neither of these failure types are a result of a casting defect the warranty

does not apply. Clearly, it is in everyone's best interest to prevent this type of failure. The maintenance of

system integrity is the best method to achieve this.

NOTICE

This boiler has a limited warranty, a copy of which is printed on the back of this manual.

It is the responsibility of the installing contractor to see that all controls are correctly installed and are

operating properly when the installation is complete.
Surface rust on cast iron sections may be attributed to the manufacturing process as well as condensation

during storage. Surface rust is normal and does not affect the performance or longevity of a boiler.