Fig. 2—dimensional drawing dimensions (in.) – Bryant 345MAV User Manual

Page 3

background image

Fig.

2—Dimensional

Drawing

DIMENSIONS

(IN.)

UNIT

SIZE

A

D

E

024040

17-1/2

15-7/8

16

036040

17-1/2

15-7/8

16

024060

17-1/2

15-7/8

16

036060

17-1/2

15-7/8

16

048060

17-1/2

15-7/8

16

036080

17-1/2

15-7/8

16

048080

17-1/2

15-7/8

16

060080

21

19-3/8

19-1/2

048100

21

19-3/8

19-1/2

060100

21

19-3/8

19-1/2

060120

24-1/2

22-7/8

23

A02147

NO

TES:

1.

Minim

um retur

n-air openings at fur

nace

, based on metal duct.

If fle

x duct is used,

see fle

x duct man

uf

acturer’

s recommendations f

or equiv

alent diameters

.

2.

Minim

um retur

n-air opening at fur

nace:

a.

F

or 800 CFM–16-in.

round or 14

1

/

2

x 12-in.

rectangle

.

b

.

F

or 1200 CFM–20-in.

round or 14

1

/

2

x 19

1

/

2

-in.

rectangle

.

c.

F

or 1600 CFM–22-in.

round or 14

1

/

2

x 23

1

/

4

-in.

rectangle

.

d.

F

or airflo

w requirements abo

ve

1800 CFM, see Air Deliv

er

y tab

le in Product Data

liter

ature f

or specific use of single side inlets

. The use of both side inlets

, a

combination of 1 side and the bottom, or the bottom only will ensure adequate

retur

n air openings f

or airflo

w requirements abo

ve

1800 CFM at 0.5”

W

.C

. ESP

.

17

5

16

"

24

1

2

"

27

9

16

"

TYP

27

5

8

"

29

11

16

"

TYP

30

13

16

"

32

5

8

"

TYP

33

1

4

"

TYP

CONDENSA

TE

DRAIN TRAP

LOCA

TION

(AL

TERNA

TE

UPFLO

W)

7

8

-IN.

DIA

A

CCESSOR

Y

PO

WER ENTR

Y

7

8

-IN.

DIA

PO

WER CONN

CONDENSA

TE DRAIN

TRAP LOCA

TION

(DO

WNFLO

W &

HORIZONT

AL LEFT)

26

15

16

"

24

1

2

"

22

5

16

"

2-IN.

COMB

USTION-

AIR CONN

1

2

-IN.

DIA

GAS CONN

2-IN.

VENT

CONN

1

2

-IN.

DIA

THERMOST

A

T

ENTR

Y

22

11

16

"

SIDE INLET

23

1

4

"

TYP

SIDE INLET

1

1

4

"

1

"

OUTLET

26

15

16

"

28

1

2

"

22

5

16

"

19

"

13

16

"

5

8

"

5

16

"

1

"

39

7

8

"

22

1

4

"

TYP

11

16

"

7

16

"

24

3

16

"

BO

TT

OM INLET

18

1

4

"

22

11

16

"

2-IN.

COMB

USTION-

AIR CONN

1

2

-IN.

DIA

GAS CONN

7

8

-IN.

DIA

PO

WER CONN

1

2

-IN.

DIA

THERMOST

A

T

ENTR

Y

2-IN.

VENT

CONN

DIMPLE LOCA

T

ORS

FOR HORIZONT

AL

HANGING

14

1

2

"

TYP

SIDE INLET

9

7

16

"

TYP

26

15

16

"

TYP

CONDENSA

TE

DRAIN LOCA

TION

(UPFLO

W)

30

1

2

"

9

16

"

TYP

CONDENSA

TE

DRAIN LOCA

TION

(UPFLO

W)

E

INLET

11

/

16

"

11

/

16

"

D

13

/

16

"

13

/

16

"

OUTLET

A

AIRFLO

W

26

1

4

"

26

1

4

"

CONDENSA

TE DRAIN

TRAP LOCA

TION

(DO

WNFLO

W &

HORIZONT

AL RIGHT)

OR AL

TERNA

TE

1

2

-IN.

DIA GAS CONN

—3—