a. Permanently install perforated disk assembly (factory-

supplied in loose parts bag) in combustion-air elbow
using RTV or by cementing. (See Fig. 35.)

For 120,000 Btuh size units only: Separate the 2 halves
of perforated disk assembly and use only the shouldered
disk half.

b. Determine length of straight portion of combustion-air

inlet pipe from table in Fig. 35.

c. Cut field-supplied 2-in diameter PVC pipe to determined

length.

d. Permanently attach elbow/perforated disk assembly to

straight portion of pipe using RTV or by cementing. (See
Fig. 35.)

TABLE 6—MAXIMUM ALLOWABLE PIPE LENGTH (FT) (CONTINUED)

ALTITUDE (FT)

UNIT SIZE

TERMINATION

TYPE

PIPE DIA

(IN.)*

NUMBER OF 90° ELBOWS

1

2

3

4

5

6

4001 to 5000‡

024040
036040

2 Pipe or 2-in

Concentric

1-1/2

60

55

50

45

44

39

2

70

70

70

70

70

70

024060
036060
048060

2 Pipe or 2-in

Concentric

1-1/2

15

10

5

NA

NA

NA

2

64

59

58

53

52

52

036080
048080
060080

2 Pipe or 2-in

Concentric

2

44

39

26

21

20

11

2-1/2

70

70

70

70

70

70

048100
060100

2 Pipe or 3-in

Concentric

2-1/2

31

22

13

12

NA

NA

3

70

70

67

62

57

52

060120

2 Pipe or 3-in.

Concentric

3† no disk

53

46

40

33

26

20

4† no disk

70

70

70

70

70

70

ALTITUDE (FT)

UNIT SIZE

TERMINATION

TYPE

PIPE DIA

(IN.)*

NUMBER OF 90° ELBOWS

1

2

3

4

5

6

5001 to 6000‡

024040
036040

2 Pipe or 2-in

Concentric

1-1/2

57

52

47

42

40

35

2

70

70

70

70

70

70

024060
036060
048060

2 Pipe or 2-in

Concentric

1-1/2

14

9

NA

NA

NA

NA

2

60

55

54

49

48

47

036080
048080
060080

2 Pipe or 2-in

Concentric

2

41

36

23

18

17

8

2-1/2

70

70

70

70

70

70

048100
060100

2 Pipe or 3-in

Concentric

2-1/2

29

21

12

11

NA

NA

3

70

67

62

57

52

47

060120

2 Pipe or 3-in.

Concentric

3† no disk

42

35

29

22

15

9

4† no disk

70

70

70

70

70

70

ALTITUDE (FT)

UNIT SIZE

TERMINATION

TYPE

PIPE DIA

(IN.)*

NUMBER OF 90° ELBOWS

1

2

3

4

5

6

6001 to 7000‡

024040
036040

2 Pipe or 2-in

Concentric

1-1/2

53

48

43

38

37

32

2

70

70

68

67

66

64

024060
036060
048060

2 Pipe or 2-in

Concentric

1-1/2

13

8

NA

NA

NA

NA

2

57

52

50

45

44

43

036080
048080
060080

2 Pipe or 2-in

Concentric

2

38

33

21

16

15

6

2-1/2

70

70

68

67

66

64

048100
060100

2 Pipe or 3-in

Concentric

2-1/2

27

19

10

9

NA

NA

3

68

63

58

53

48

43

060120

2 Pipe or 3-in.

Concentric

3† no disk

31

24

18

11

NA

NA

4† no disk

70

70

70

70

67

62

ALTITUDE (FT)

UNIT SIZE

TERMINATION

TYPE

PIPE DIA

(IN.)*

NUMBER OF 90° ELBOWS

1

2

3

4

5

6

7001 to 8000‡

024040
036040

2 Pipe or 2-in

Concentric

1-1/2

49

44

39

34

33

28

2

66

65

63

62

60

59

024060
036060
048060

2 Pipe or 2-in

Concentric

1-1/2

12

7

NA

NA

NA

NA

2

53

48

46

41

40

38

036080
048080
060080

2 Pipe or 2-in

Concentric

2

36

31

19

14

12

NA

2–1/2

66

65

63

62

60

59

048100
060100

2 Pipe or 3-in

Concentric

2–1/2

25

17

8

7

NA

NA

3

63

58

53

48

43

38

060120

2 Pipe or 3-in.

Concentric

3† no disk

20

13

7

NA

NA

NA

4† no disk

61

56

51

46

41

36

See notes at end of table

—26—