4.3.2.2 Access point

The following is the setting procedure for the access point.

Step 1 Setting the 802.1X function at the access point
Make settings for the 802.1X function.
The following procedure is to enable the 802.1X function. The other settings of the [Basic setting] and [Access
restriction] tabs are omitted.

1.

Start the access point setting utility.

2.

Select the [WEP] tab.

3. 802.1X

group

Select [Make 802.1X authentication (permit non-802.1X station to coexist] in the [802.1X]
component box.
Place a check mark in the [Distribute WEB key] check box.
Place a check mark in the [Reauthenticate during WEP key distribution] check box.
Set 600 in the [WEP key change interval] edit box.
Select the [Key length] radio button of [13 byte].

4. WEP

group

Set a 13-bytes WEP key in [key 1].