beautypg.com

Konica Minolta Bizhub 215 User Manual

Page 142

background image

bizhub 215

9-3

9.1

Primary messages and corrective actions

9

[MEMORY FILE FULL]

The maximum number of memo-
ry files has been used during fax
transmission.

Remove the received data that is
saved in the memory.

[MEMORY FILE FULL]

The maximum number of memo-
ry files has been used during fax
receiving.

Remove the received data that is
saved in the memory.

[CANNOT CONNECT]

An error has occurred during
connection with the server.

Reconfigure network settings in
the Utility screen. If this error re-
curs after a communication has
restarted, contact your network
administrator.

[CANNOT GET IP]

Cannot obtain the IP address.

Respecify the IP address in the
Utility screen. If this error recurs
after a communication has re-
started, contact your network
administrator.

[WRONG PASSWORD]

Cannot connect to the POP3
server due to entry of an incor-
rect password.

Specify the correct POP3 pass-
word in the Utility screen. If this
error recurs after a communica-
tion has restarted, contact your
network administrator.

[RECEIVE WRONG DATA]

Data that cannot be printed on
this machine was received. (The
attached file is not of the TIFF-F
type.)

Ask the sender to send a TIFF-F
file or correct type of text file.

[SERVER MEMORY FULL]

A memory overflow has occurred
in the transmission server during
Internet fax transmission.

Delete the transmission data that
is saved in the memory.

Error code: 0027

This machine is currently ac-
cessing the administrator mode
of PageScope Web Connec-
tion
, LSU, or RSD.

Log out from PageScope
Web Connection
.

Disconnect the LSU.

If no operation is performed
for 600 seconds, the display
returns to the basic screen.

For an RSD communication,
consult your service repre-
sentative.

Message

Cause

Correction action