1. CHARACTERISTICS AND SPECIFICATIONS
All Min/Max characteristics and specifications are guaranteed over the Specified Operating Conditions. Typical
performance characteristics and specifications are derived from measurements taken at nominal supply voltages
and T
A
= 25°C.
SPECIFIED OPERATING CONDITIONS
(AGND, DGND = 0 V, all voltages with respect to 0 V)
ABSOLUTE MAXIMUM RATINGS
(AGND, DGND = 0 V; all voltages with respect to 0 V. Operation beyond these limits may result in permanent dam-
age to the device. Normal operation is not guaranteed at these extremes.)
Notes:
1. Transient currents of up to 100 mA will not cause SCR latch-up.
Parameter
Symbol Min Typ
Max
Units
Power Supply Voltage
VA
VD
VL
3.13
3.13
3.13
3.3
3.3
3.3 or 5.0
3.46
3.46
5.25
V
V
V
Ambient Operating Temperature:
Commercial Grade
Automotive Grade
T
A
-10
-40
-
-
+70
+85
°C
Parameter
Symbol
Min
Max
Units
Power Supply Voltage
VA, VD,VL
-
6.0
V
Input Current, Any Pin Except Supplies
I
in
-
±10
mA
Input Voltage
V
in
-0.3
(VL) + 0.3
V
Ambient Operating Temperature (power applied)
T
A
-55
125
°C
Storage Temperature
T
stg
-65
150
°C