8. BASIC APPLICATION CIRCUITS

The CS5490 is configured to measure power in a
single-phase, two-wire single voltage and current
system, as illustrated in

Figure 21

. In this diagram, a

current transformer (CT) is used to sense the line load
current, and a resistive voltage divider is used to sense
the line voltage.

CT

CS5490

Line

N

VIN-

VIN+

IIN+

IIN-

Application

Processor

RESET

RX

TX

GNDA

DO

VDDA

+3.3V

0.1µF

0.1µF

+3.3V

VDDD

+3.3V

VREF-

VREF+

0.1µF

Wh

4.096 MHz

XIN

XOUT

1K

MODE

5 x250K

1K

LOA D

0.1 µF

10K

+3.3V

27nF

27nF

1K

1K

½ R

BURDEN

½ R

BURDEN

27nF

27nF

Figure 21. Typical Connection Diagram (Single-phase, Two-wire, Power Meter)