A. Technical appendix

A−12

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

1

Ready for teaching

2

Value transferred

1

0

ACK_Teach

Teach_
Actual_Value

1

2

1

0

Fig. A/2:

Handshake when teaching

Note:
The drive must not stand still for teaching. However, a speed
of 1 m/s means that the actual position changes by 1 mm
every millisecond. With the usual cycle times of the PLC + field
bus + motor controller there will be inaccuracies of several
millimetres even at a speed of only 100 mm/s.

Overview of parameters involved (see appendix B.1.2)

Parameters involved

Description

PNU

Teach target

520

Record number

400

Start

SFC_DC_CONTROL ć Teach_Actual_Value = falling edge: Teach value

Reply message

SFC_DC_CONTROL ć Ack_Teach = 1: Value transferred

Prerequisites

Device control via PLC/field bus (Drive_Control_FCT_HMI = 0)
Controller in status Drive enabled" (Drive_enabled = 1)

Tab. A/8:

Teach parameters involved