Station status 2 (only SFC−DC related bits)

Station status 2

Bit

Meaning

Explanation

0

Diag.Prm_Req

1 = The master must configure the SFC−DC again

1

Diag.Stat_Diag

1 = The master must request diagnostic data until this

bit is set to 0

2

Ĉ

Always 1 (set to logical 1 by the SFC−DC)

3

Diag.WD_On

1 = Response monitoring/watchdog activated

4

Diag.Freeze_Mode

1 = Freeze activated

5

Diag.Sync_Mode

1 = Sync activated

6

Ĉ

Reserved

7

Diag.Deactivated

Always 0 (always reset to 0 by the SFC−DC)

Tab. A/18:

Diagnostic bits of station status 2

Station status 3

Station status 3

Bit

Meaning

Explanation

0...6

Ĉ

Reserved

7

Diag.Ext_Diag_Overflow

Is always logical 0 (set by the SFC−DC)

Tab. A/19: