beautypg.com

Festo Контроллер двигателя SFC-ST User Manual

Page 92

background image

A. Technical appendix

A−8

Festo P.BE−SFC−DC−PB−S7−E N en 0604NH

Overview of parameters involved (see also appendix B.1.2)

Parameters involved

Description

PNU

Offset axis zero point

1010

Reference method (permitted: 7, 11, −18, −17)

1011

Reference travel speed

1012

Reference travel required

1014

Reference travel maximum torque

1015

Start

SFC_DC_CONTROL ć Start_Positioning_Task = positive edge

Reply message

SFC_DC_CONTROL ć Ack_Start = positive edge: Quit Start
SFC_DC_CONTROL ć Drive_is_referenced = Drive is referenced

Prerequisites

Device control via PLC/field bus (Drive_Control_FCT_HMI = 0)
Controller in status Drive enabled" (Drive_enabled = 1)
No command for jogging

Tab. A/4:

Parameters involved in reference travel

Reference travel methods

hex

dec.

Description

07h

7

Search for reference switch in positive direction. The reference position lies
at the first index pulse in the negative direction; the reference switch supĆ
plies a 0−signal.

0Bh

11

Search for reference switch in negative direction. The reference position
lies at the first index pulse in the positive direction; the reference switch
supplies a 0−signal.

EFh

−17

Search for negative stop. The point found is the reference position. As the
axis must not stand still at the stop, the offset axis zero point must be

š 0.

EEh

−18

Search for positive stop. The point found is the reference position. As the
axis must not stand still at the stop, the offset axis zero point must be

š 0.

Tab. A/5:

Overview of reference travel methods