Festo Контроллер двигателя SFC-ST User Manual
Page 92

A. Technical appendix
A−8
Festo P.BE−SFC−DC−PB−S7−E N en 0604NH
Overview of parameters involved (see also appendix B.1.2)
Parameters involved
Description
PNU
Offset axis zero point
1010
Reference method (permitted: 7, 11, −18, −17)
1011
Reference travel speed
1012
Reference travel required
1014
Reference travel maximum torque
1015
Start
SFC_DC_CONTROL ć Start_Positioning_Task = positive edge
Reply message
SFC_DC_CONTROL ć Ack_Start = positive edge: Quit Start
SFC_DC_CONTROL ć Drive_is_referenced = Drive is referenced
Prerequisites
Device control via PLC/field bus (Drive_Control_FCT_HMI = 0)
Controller in status Drive enabled" (Drive_enabled = 1)
No command for jogging
Tab. A/4:
Parameters involved in reference travel
Reference travel methods
hex
dec.
Description
07h
7
Search for reference switch in positive direction. The reference position lies
at the first index pulse in the negative direction; the reference switch supĆ
plies a 0−signal.
0Bh
11
Search for reference switch in negative direction. The reference position
lies at the first index pulse in the positive direction; the reference switch
supplies a 0−signal.
EFh
−17
Search for negative stop. The point found is the reference position. As the
axis must not stand still at the stop, the offset axis zero point must be
š 0.
EEh
−18
Search for positive stop. The point found is the reference position. As the
axis must not stand still at the stop, the offset axis zero point must be
š 0.
Tab. A/5:
Overview of reference travel methods