Commissioning, Startup, Operation, and Shutdown
Doweling the pump casing
You must dowel the pump casing to the baseplate pedestals in order to maintain the proper
pump position. There are two methods for doweling the pump casing, depending on whether
the pump is used in a cold application or a hot application.
Use this table to determine whether hot doweling is required.
Stage length
Pump size
Temperature threshold for hot
doweling
3
all others
N/A
6x8-14
370°F (188°C)
8x10-13
340°F (171°C)
10x12-14.5
320°F (160°C)
4
all others
N/A
6x8-11D
360°F (182°C)
6x8-13
6x8-14
330°F (166°C)
8x10-13
300°F (149°C)
10x12-14.5
280°F (138°C)
5
all others
N/A
4x6-10D
370°F (188°C)
4x6-11D
6x8-11
6x8-11D
330°F (166°C)
6x8-13
6x8-14
300°F (149°C)
8x10-13
270°F (132°C)
10x12-14.5
250°F (121°C)
6
all others
N/A
4x6-10
380°F (193°C)
4x6-10D
360°F (182°C)
4x6-11
4x6-11D
340°F (171°C)
6x8-11
6x8-11D
300°F (149°C)
6x8-13
6x8-14
270°F (132°C)
8x10-13
240°F (116°C)
10x12-14.5
225°F (107°C)
7
all others
N/A
3x4-9
390°F (199°C)
4x6-10
350°F (177°C)
4x6-10D
330°F (166°C)
4x6-11
4x6-11D
310°F (154°C)
6x8-11
6x8-11D
270°F (132°C)
6x8-13
6x8-14
250°F (121°C)