Setting the low battery warning level (mode 3), Camera operation – ARRI ARRIFLEX 416 User Manual
Page 66

Setting the Low Battery warning level (Mode 3)
When the 416 is not powered by an OBB-2, it is possible
to set the threshold at which the Low Battery warning is
triggered. It can be set anywhere between 20.0 and 29.9
volts.
• Change from Mode 1 to Mode 3 by pressing the
“MODE” button twice.
• Press the “SET“ button. The currently set Low Battery
warning level is displayed for 3 seconds.
• To change the level, press the “SEL“ button 3 times to
select the 2nd voltage digit or 4 times to select the 3rd
voltage digit. The selected digit will blink.
• Adjust the blinking digit with the “SET“ button.
• Once the 2nd and 3rd voltage digits are set as
required, press the “SEL“ button once to exit the
adjustment mode.
Camera
Operation
MODE button
SEL / SET buttons