Timecode – ARRI ARRIFLEX 416 User Manual
Page 181
![background image](/manuals/45749/181/background.png)
11
Upper Line 3rd Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F
Warning
Remedy
• • • • • • • •
no meaning on 416
N/A
• • • • • • • •
TC not set to NDF/RT
reset TC at current frame rate
and swiched to RT/NDF
RT (Real Time) is 24, 25, 30 fps
NDF (Nondrop Frame)
is 23,976 and 29,97 fps
• • • • • • • •
TC LED not recognized
fit or check TC module
• • • • • • • •
TC not buffered
reset TC;
either the TC buffer capacitor
was not (yet) charged or the
power supply was insufficient
or interrupted
Upper Line 4th Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F
Warning
Remedy
• • • • • • • •
error in external synchronization resynchronize
or check LTC-signal
• • • • • • • •
TC switched on but not set
set TC
• • • • • • • •
TC not ready
functional error
have the camera checked
at an authorised ARRI Service Centre
Timecode