10
Upper Line 1st Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F
Warning
Remedy
• • • • • • • •
no valid TC frame rate
set correct TC frame rate
or switch off TC
• • • • • • • •
no meaning on 416
N/A
• • • • • • • •
no meaning on 416
N/A
• • • • • • • •
the last take has no
briefly depress the „PHASE“-button,
or intermittent TC
or reshoot
Upper Line 2nd Digit for TC Warnings
0 1 2 3 4 5 6 7 8 9 A b C d E F
Warning
Remedy
• • • • • • • •
more than 8 hours
reset TC
since TC was last set
• • • • • • • •
TCS values not valid
reset TCS value
• • • • • • • •
ESU frame rate
check ESU frame rate
outside TC range
(display Mode 1)
and TC generator frame rate
(Mode 4);
max. allowable difference is 1 %
• • • • • • • •
no TC with variable speed
switch off variable speed accessory
or TC as TC-operation with variable
speed is not possible