Installation

510969

26

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Figure 17

D816I

1

3-Wire Grounded Neutral 120/240 Volt, 60 Hertz
AC 1 Phase Service Entrance Switch Box
(See NOTE above)

4

Metallic or Non-Metallic Sheathed Cable
(Copper wire only)

5

Pigtail to Dryer (See NOTE above)

2

30 Ampere Fuses or Circuit Breaker

6

Neutral

3

Neutral Wire

7

Terminal Block in Dryer

NOTE: The power cord (pigtail) is NOT supplied with the electric
dryer. Type of pigtail and gauge of wire must conform to local
codes and instructions.

The method of wiring the dryer is optional and subject to local
code requirements.

NOTE: Connect the dryer to the power supply with the
MAXIMUM RATED VOLTAGE listed on the nameplate.

1

2

3

4

5

6

7

POWER SUPPLY

POWER SUPPLY

INTERMEDIATE
FUSE BOX (May
be omitted if
service entrance
box is fused)

WALL RECEPTACLE

PIGTAIL CONNECTION

L1

L2

L1

L2

DIRECT CONNECTION

INTERMEDIATE
SHUT-OFF
(May be
omitted if
service
entrance box is
fused)

120 ± 12

V.A.C.

A typical

30-Amp

Three-wire

Receptacle

NEMA Type

10-30R

120 ± 12

V.A.C.

240 ± 12

V.A.C.

NOTE: Use COPPER WIRE only.

k

Shorter than 15

k (4.5 m) use 10 A.W.G.

Longer than 15

k (4.5 m) use 8 A.W.G.