Heat source check – Alliance Laundry Systems D677I User Manual
Page 23

Installation
21
510969
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Heat Source Check
Electric Dryers
Metered Models
Set the proper FABRIC SELECTOR switch at
NORMAL. Place coins in the slide and carefully push
slide in as far as possible. IN USE light will come on
indicating the dryer is ready to operate. Close the
loading door and press the PUSH-TO-START button
firmly to start the dryer. After the dryer has operated
for three minutes, the exhaust air or exhaust pipe
should be warm.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and
turn timer knob to 50. Close the loading door and press
the PUSH-TO-START button. IN USE light will
come on indicating start of cycle. After the dryer has
operated for three minutes, the exhaust air or exhaust
pipe should be warm.
Gas Dryers
During the gas heat check, observe the burner flame.
The flame can be viewed by removing the lower front
panel of the dryer.
Metered Models
Set FABRIC SELECTOR switch at NORMAL. Place
coins in the slide and carefully push slide in as far as
possible. IN USE light will come on indicating the
dryer is ready to operate. Close the loading door and
press the PUSH-TO-START button firmly. The dryer
will start, the igniter will glow red and the main burner
will ignite.
Nonmetered Models
Set FABRIC SELECTOR switch at NORMAL and
turn timer knob to 50. Close the loading door and press
the PUSH-TO-START button. IN USE light will
come on indicating start of cycle, igniter will glow red
and main burner will ignite.
IMPORTANT: If all air is not purged out of the
gas line, the gas igniter may go off before the gas is
ignited. If this happens, after approximately two
minutes the igniter will again attempt gas ignition.