10.9 Cable glands

CABLE GLANDS SELECTION TABLE

Zone - Gas

Cable gland
type

Certification Operating

temperature

Cable

Cable glands
part code

External
diameter
(mm)

Diameter
under
armour
(mm)

IIC
Zone 1 or
Zone 2

Barrier

IECEX / ATEX /
GOST

-60 / +80°C
-76 / 176°F

Not armored

OCTEXB3/4C

13 - 20.2

-

IIB
Zone 1

Armored

OCTEXBA3/4C

16.9 - 26

-

IIB o IIA
Zone 2

With gasket

IECEX / ATEX /
GOST

-60 / +100°C
-76 / 212°F

Not armored

OCTEX3/4C

13 - 20.2

-

Armored

OCTEXA3/4C

16.9 - 26

11.1 - 19.7

ATEX

-20 / +80°C
-4 / 176°F

Not armored

OCTEX3/4

14 - 17

-

Armored

OCTEXA3/4

18 - 23

14 - 17

Tab. 06

11 Technical drawings

j

The values are in millimeters.

Ø 410

296

60

80

385

421

= 336 =

80

14

385

= 336 =

Fig. 18

EXDTRX3, EXDTRX324