EN - English - I

nstruc

tions manual

18

6.2.24 Dip switch SW6 and SW4
configuration table

SW6

Dip

Position

Function

1

ON

PELCO D protocol

1

OFF

VIDEOTEC or MACRO
protocols (setting the dip 8
of SW4)

2, 3, 4

Indifferent

No function

SW4

Dip

Position

Function

1, 2

OFF, OFF

9600 baud* (VIDEOTEC and
MACRO), 2400 PELCO D

1, 2

ON, OFF

300 baud VIDEOTEC, 38400
baud MACRO, 4800 baud
PELCO D

1, 2

OFF, ON

1200 baud (VIDEOTEC and
MACRO), 9600 baud PELCO D

1, 2

ON, ON

19200 baud (VIDEOTEC,
MACRO and PELCO D)

3

OFF

Unused alarms*

3

ON

Used alarms

4

OFF

N.C. alarms*

4

ON

N.O. alarms

5

OFF

-

5

ON

Alarms on Aux4

6

OFF

-

6

ON

To release Aux3 and Aux4

7

OFF

-

8

ON**

VIDEOTEC standard
protocol****

8

OFF***

MACRO protocol **** ((DCIR,
DCJ, DCT and DCTEL)

Tab. 04 * Default settings.

** Compatible with keyboards DCIR, DCJ, DCT and
DCTEL with VIDEOTEC standard protocol.
*** Compatible with keyboards DCIR, DCJ, DCT and
DCTEL with MACRO protocol.
**** Selectable only if the dip 1 of SW6 is in OFF
position.

6.2.22.1 Example of Patrol sequence
programming.

If you want to set up a Patrol sequence that starts
from Preset position 19, ends at Preset position 33
and stops for one minute at every position reached:

  

: Enables parameter insertion;

  

: Start Patrol at position 19;

  

: End Patrol at position 33;

  

: Pause of 60 seconds at every position

reached;

  

: Start of sequence;

  

: End of sequence.

6.2.23 Switching on and switching off

Before connecting the unit:
• Make sure that the goods supplied correspond

to the required specifications by controlling the
rating plates ("4.2 Product markings", page 7);

• Make sure that the fuses of the EXDTRX3 /

EXDTRX324 receiver are not damaged;

• Make sure that the receiver and the other

components of the plant are closed in order to
avoid the direct contact with live elements;

• Make sure that all parts are accurately and firmly

fixed;

• The power cords must not hamper the normal

operations of the installer and the movement of
the positioning device;

• Make sure that all power sources and the

connecting cables are able to bear the system
consumption.