beautypg.com

ARI Armaturen ARI-PREMIO Plus EN User Manual

Page 34

background image

Page 34

0040501004 5010

Operating and installation instructions

Thrust actuator ARI-PREMIO-Plus

If a position is programmed for a switched Force switch, e.g. in a final position, the
corresponding relay is only switched if this Force switch is actuated, regardless of the
position. This can be the case if a blockage occurs, for instance. A blockage additionally
results in a "Failure" signal because the desired position cannot be reached.
5.7.1.2 Technical data

5.7.1.3 Installation procedure

5.7.1.4 Electrical connection

Bild 19

Type

Relay
1 Position

2 Position

3 Warning

4 Failure

Switching capacity: U

B

6 A / 250 V~

2 A / 30 V AC/DC~

Max. conductor cross-section 2.5 mm²

1.5 mm²

Contact material

Gold

Gold

Storage temperature

-40°C to +85°C

Operating temperature

-20°C to +70°C

Fig. 17

Fig. 18