2 feedback – ARI Armaturen ARI-PREMIO Plus EN User Manual
Page 11

0040501004 5010
Page 11
Operating and installation instructions
Thrust actuator ARI-PREMIO-Plus
4.5.2 Feedback
Description
Required option
Position
(analog)
4-20mA DC
- Measuring resistance (Burden)
max. 500 Ohm
- Signal resolution 8 Bit
- Analog output card PREMIO-Plus
0-10V DC
- Measuring resistance (Burden)
max. 2 kOhm Burden
- Signal resolution 8 Bit
- Analog output card PREMIO-Plus
Modbus
- Protocol: Modbus, Modbus-
integer
- Baud rate: 9600, 19200, 38400
- Device adress: 0 ... 255
- Max. number of participants: 32
- Analog output card PREMIO-Plus
- dTRON 316
with RS422/485 card (dTRON options);
it is 1 analog input for position feedback on
dTRON needed
Profibus-DP
- Device adress: 0 ... 255
- Analog output card PREMIO-Plus
- dTRON 316
with Profibus card (dTRON options);
it is 1 analog input for position feedback on
dTRON needed
Position 2x
- Intermediate positions
- End positions
Change over contact
230V 6/3A
- Relay card PREMIO-Plus
Modbus
- Protocol: Modbus, Modbus-
integer
- Baud rate: 9600, 19200, 38400
- Device adress: 0 ... 255
- Max. number of participants: 32
- Relay card PREMIO-Plus
- dTRON 316
with RS422/485 card and at more than
2 binary feedbacks is the binary input card
required (dTRON options)
Profibus-DP
- Device adress: 0 ... 255
- Relay card PREMIO-Plus
- dTRON 316
with Profibus card and at more than
2 binary feedbacks is the binary input card
required (dTRON options)
Failure signal
- Control signal failure
- Position can not
be achieved
(motor / gear failure)
- Blockage (actual)
- Actuator is not initialized
- Power failure
Change over contact
30V AC/DC 2A
- Relay card PREMIO-Plus
Modbus
- Protocol: Modbus, Modbus-
integer
- Baud rate: 9600, 19200, 38400
- Device adress: 0 ... 255
- Max. number of participants: 32
- Relay card PREMIO-Plus
- dTRON 316
with RS422/485 card and at more than
2 binary feedbacks is the binary input card
required (dTRON options)
Profibus-DP
- Device adress: 0 ... 255
- Relay card PREMIO-Plus
- dTRON 316
at Profibus card and at more than 2 binary
feedbacks is the binary input card required
(dTRON options)