Figure 12, Measurement paths of wmt700 – Vaisala WMT700 User Manual
Page 39

Chapter 3 _______________________________________________________ Functional Description
The microcontroller calculates WS from the measured transit
times using the following formula:
)
t
/
1
(1/t
L
5
.
0
V
r
f
W
−
⋅
⋅
=
where
V
w
=
Wind velocity
L
=
Distance between two transducers
t
f
=
Transit time in the forward direction
t
r
=
Transit time in the reverse direction
Measuring the six transit times allows V
w
to be computed for each
of the three ultrasonic paths. Using V
w
values of two array paths
is enough to compute WS and WD.
Figure 12 below shows the different paths of WMT700 and the
vectors provided by the wind sensor:
1104-066
Figure 12
Measurement Paths of WMT700
where
1–6
=
Measurement paths 1 to 6 of WMT700
L
a
, L
b
, L
c
=
Distance between two transducers
VAISALA ________________________________________________________________________ 37