Chapter 5 _________________________________________________________________ Operation
Table 35
List of Configuration Mode Commands
Command
Description
?
Displays a list of configuration commands.
BAUD
Changes or displays serial port settings.
CLEARERR Resets error counters.
CLOSE
Switches the serial port to measurement mode.
ERRORS
Fetches the error codes and counter information from WMT700.
G
Displays either all or specified parameters.
H
Displays a list of data messages and available values for
measurement unit, profile, baud rate, interface, and analog
output mode.
MEAS
Starts wind measurement based on the user-configurable
averaging time. WMT700 does not send data messages
automatically.
POLL
Tests data polling.
RESET
Resets WMT700.
S
Changes selected parameters or defines new data messages.
START
Starts continuous measurement.
STOP
Stops continuous measurement.
VERSION
Displays the software version.
WIND_GET Fetches wind calibration information.
Parameter Handling Commands
All the commands in the configurating mode are in the following
form:
>CMD x,y
| | | | | | |___ Press Enter key to activate the command
| | | | | |_______Value of the parameter
| | | | |_______ Comma
| | | |________ Any parameter in Table 66 on page 205
| | |__________ Space
| |______________ Command
|_________________ Configuration mode prompt
The parameter name and allowed parameter values depend on the
command. For certain commands they are optional. In the
following command descriptions, WMT700 configuration mode
prompt and enter are left out for clarity.
VAISALA _______________________________________________________________________ 111