WS425 F/G ASOS Profile
Configurable Parameters
Table 43 below lists the configurable parameters and their
allowed and default values for the WS425 F/G ASOS profile.
Table 43
Configurable Parameters for WS425 F/G ASOS
Profile
Parameter
Default
Value
Profile-Specific Allowed
Values
Description
autoSend
0
0 = Automatic messages
disabled
Automatic data message number.
Selects the data message format for
automatic messages
com1_protocol
0*
2 = WS425 F/G ASOS
Profile for serial port COM1
com2_protocol 2
2 = WS425 F/G ASOS
Profile for serial port COM2
com2_interf
N/A**
0 = RS-485
1 = RS-422
3 = RS-232
Interface for serial port COM2
wndAvg
5
0.25 … 3600
Resolution: 0.25
Averaging time for wind
measurement in seconds
wndGustTime
3
0.25 … 3600
Resolution: 0.25
Averaging time for wind minimum and
maximum in seconds
wndOrientation
0
0 = Array facing up
1 = Array facing down
Orientation of the array of WMT700
wndUnit
0**
0 = Meters per second (m/s)
1 = Miles per hour (mph)
2 = Kilometers per hour (km/h)
3 = Knots (knot)
Wind speed unit
wndVector
0
0 = Scalar averaging
Wind averaging method
* The parameter has no protocol-specific default value. It is determined
separately in the configuration code.
**
Wind speed unit and COM2 digital communication interface are defined in
the order form. Default setting may be any of the allowed options, and it can be
verified from the unit’s configuration code.
To start continuous measurement, use the START command.
You can stop the measurement with the STOP command. For
instructions, refer to section Wind Measurement Control
Commands on page 115.