Table 42 – Vaisala WMT700 User Manual
Page 142

User's Guide ______________________________________________________________________
Table 42
Required Parameters for WS425 Analog
Output Operation Mode
Parameter Name
Default Value Allowed Values
Description of How to Emulate WS425
aout1err
1000
0 …. 32000
Set 1 for voltage output and 625 for
frequency output for similar operation as
with WS425.
aout1_g
1
0 …. 100
Gain for AOUT1.
Set 0.017895 for compatibility with WS425
voltage output.
Set 11.18 for compatibility with WS425
frequency output.
aout2_g
1
0 …. 100
Gain for AOUT2.
Set 0.0027855 for compatibility with
WS425 potentiometer output.
aout1mode
3
0 = Current
1 = Voltage
2 = Frequency
3 = Disabled
Analog output mode for AOUT1.
Set 1 for WS425 voltage output
compatibility.
2 for WS425 frequency output
compatibility.
aout2mode
7
4 = Current
5 = Voltage
6 = Potentiometer
7 = Disabled
Analog output mode for AOUT2.
Set 6 WS425 potentiometer output
compatibility.
aout1_o
aout2_o
0
-10000 … 10000
Offset for AOUT1 and AOUT2.
Set output offset to 0.
For configuration instructions, see section Configuration on page
110.
140 __________________________________________________________________ M211095EN-E