3 corrective maintenance, 3 corrective maintenance -4 – EOTech MIPIM (AN/PEQ-16B) - Mini Integrated Pointer Illuminator Module User Manual
Page 56

3-4
3.2 PREVENTIVE MAINTENANCE - Continued
Laser Ports and Reflector Assembly
Inspect the laser ports and Reflector Assembly Cover for
dirt, dust, and grime. Remove any large particles or loose
dirt using air or a lens brush. Fine cleaning of the optical
surfaces should be performed using an optical cloth and
cleaning solution. Avoid using excessive force as this may
scratch the lenses.
Remote Jack
Inspect the remote jack for corrosion, dirt and damage.
Gently remove any large particles of foreign matter and
clean the contacts using a cotton swab dipped in isopropyl
alcohol.
3.3 CORRECTIVE MAINTENANCE
The MIPIM has no internal parts or assemblies replaceable
by the operator or organizational level personnel. See
section 3.4 for guidance regarding maintenance and/or
repair actions beyond those described in this manual.
Replacing Battery Cap O-Ring
1. Unscrew the battery cap until it comes free of the battery
compartment threads.
2. Use the fingers of one hand to squeeze the battery cap
o-ring while simultaneously pushing it out of its retaining
groove. Grasp the o-ring with fingers of the other hand
and pull it off the battery compartment threads.