2 preventive maintenance, 2 preventive maintenance -2 – EOTech MIPIM (AN/PEQ-16B) - Mini Integrated Pointer Illuminator Module User Manual
Page 54

3-2
3.1 TROUBLESHOOTING - Continued
Table 3-1 Troubleshooting Procedures – Continued
Symptom
Malfunction
Corrective Action
2. White Light
Illuminator appears
weak or fails to
come on when
activated.
a. Software overload.
a. Cycle power.
b. Mode Switch is in the O
OFF position.
b. Turn Mode Switch to
desired position. Activate by
pressing the FIRE button.
c. White Light Lens Cap is
preventing white light
emission.
c. Uninstall the White Light
Lens Cap.
d. Battery power is low.
d. Replace batteries.
e. Reflector assembly is
obscured by dirt, dust, or
grime.
e. Clean reflector assembly.
See section 3.2.
f. Battery compartment and/or
contacts corroded.
f. Clean battery
compartment and contacts.
See section 3.2.
3. Laser(s) and/or
White Light
Illuminator turn off
unexpectedly.
a. Automatic turn-off feature
has been activated.
a. “Wake” the system by
pressing the FIRE button.
b. Battery power is low.
b. Replace batteries.
c. Battery compartment
and/or contacts corroded.
c. Clean battery
compartment and contacts.
See section 3.2.
3.2 PREVENTIVE MAINTENANCE
The operator should inspect the MIPIM before each use and
after it has been in extreme conditions, such as prolonged
exposure to intense temperatures. The following procedures
will prolong the life of the MIPIM and help ensure safe
operation.
WARNING
Prior to performing any inspection or maintenance
procedure, verify that batteries are not installed.