Table 2-6 ir illuminator pulse rates – EOTech MIPIM (AN/PEQ-16B) - Mini Integrated Pointer Illuminator Module User Manual
Page 49

2-23
2.8 USING THE LASERS - Continued
c. Release the FIRE Button. Successful programming
will be indicated by three orange flashes on the LED
Status Indicator. If programming was unsuccessful,
the LED Status Indicator will display a steady red
light for two seconds. The set pulse rate will remain
until it is programmed differently.
NOTE
To ensure successful programming, the Mode
Selector must be turned to the desired pulse rate
within 5 seconds of pressing the FIRE Button.
Table 2-6 IR Illuminator Pulse Rates
Pulse Rate
Mode Selector Position
Continuous (no pulse)
AL
1 pulse per second
DL
4 pulses per second
AH*
8 pulses per second
DH*
* The safety screw must be removed to program these pulse rates.
2.9 USING THE WHITE LIGHT ILLUMINATOR
White Light Illuminator modes of operation are selected and
activated as described in section 2.7. The White Light
Illuminator provides a beam of white light energy for visible
illumination of the intended target area. It provides for facial
recognition out to at least 25 meters.