beautypg.com

Vt quick reference guide, Troubleshooting step 7: can power module led 3, Quick reference guide – Ag Leader Versa DirectCommand ISOBUS Quick Reference Guides User Manual

Page 14: Can power module, Start

background image

14

VT Quick Reference Guide

Quick Reference Guide

AL: 2006300 - ENG Rev C

Is voltage

correct?

Troubleshooting Step 7: CAN Power Module LED 3

Start

Using a Voltmeter Check for

12v Across Pins 2 and 4 of

ISO Connector

Check for 12V across Pin C

of High Current Relay Module

and Ground.

LED#3

Illuminated

GREEN?

Yes

No

No

CAN B Relay Failed.

Contact Ag Leader

Dealer to Replace Module.

Yes

LED Failed.

Contact Ag Leader Dealer to

replace module.

No

Check 30 Amp Fuse of High

Current Relay Module.

Yes

4/J

3/B

2/C

1/A

Is

voltage correct?

4-pin Square

Weather

Pack with

Towers

Power

Control

CAN

POWER

MODULE

CAN A

Relay

CAN B

Relay

LED

1

LED

2

LED

3

Ground

60

amp

fuse

30

amp

fuse

High Current

Relay Module

2-pin Metri-Pak

LED #3 (Green) indicates ISOBUS/CAN B is being provided high current power (+12V) across

pins 2 and 4 of ISO Plug from CAN B relay.

Troubleshooting

complete. System should be

in field-ready state.