Smi-s access failures – HP SAN User Manual
Page 58
To set up the SNMP Read Community, complete the following steps:
1.
Open a telnet session for the switch.
2.
Enter the agtcfgset command.
3.
Configure the Read only community string (Community (ro): ) for SNMP community and trap
recipient configuration. The default value of the community string is public.
4.
Enter the default IP address (0.0.0.0) or the IP address of the host where HP SAN Visibility v5.1
is installed for SNMP access list configuration.
5.
Close the telnet session.
SMI-S Access failures
While collecting data through SMI-S for Brocade switches, if there are any connection failures to the
switches or if the SMI agent is stopped, then the data collection falls back to SNMP, and a report is
generated.
For more information, contact HP or visit Servers & Storage expertise center at:
Changing SNMP proxy settings for HP StorageWorks 8/20q
and QLogic FC switches
To change the SNMP proxy setting parameter for HP StorageWorks 8/20q and QLogic FC switches,
complete the following steps:
1.
Login to the switch you want to change the SNMP proxy settings.
2.
Run the admin start command to start the session in admin mode.
3.
Run the following command: set setup snmp.
4.
Set the SNMP proxy parameter (ProxyEnabled) to "False”.
5.
Save and exit from the session.
Troubleshooting
58