Displaying ShadowImage - FlashCopy Pair Status: FCQUERY

The FCQUERY command can be used to display ShadowImage - FlashCopy pair status. The following

shows an example of FCQUERY command.
Example: FCQUERY Command

Cautions on Switching Off the Power Supply When Using ShadowImage -

FlashCopy

If you have to switch off the power supply of the disk array during ShadowImage - FlashCopy operations,

make sure to complete copying for the ShadowImage - FlashCopy pair, and then switch off the power

supply. If the shared memory is volatilized when you switch on the power supply again, the following

conditions occur:

The relationship of the ShadowImage - FlashCopy pair is deleted.

The T-VOL of the ShadowImage - FlashCopy pair is blocked.

Troubleshooting

General ShadowImage Troubleshooting

If an SI390 error code or message is displayed on the Command View management station or XP Remote

Web Console, refer to

ShadowImage Error Window

” on page 92 for a description of the SI390 error

codes and recommended corrective action.

NOTE:

Make sure to copy the SVP configuration information onto floppy disks) using the FD Dump Tool

and give the floppy disk(s) to HP service personnel.

The following table provides general troubleshooting instructions for SI390 operations.

ANTF0090IF CQUERY Formatted

DEVN SSID LSS CCA CU SERIAL STATUS

0A4D 2830 03 0D 2105 0000325476 FC . . . . . 88%

____ 2830 03 07 2105 0000325476 FC . . . . . . . .

Table 42

Status displayed by FCQUERY command

Displayed Status

Description

SIMPLEX

Volume is in the simplex status.

XRC

Volume used by Compatible Replication for IBM XRC source volume.

PPRC

Volume of a PPRC pair.

FC xxx%

Volume of ShadowImage - FlashCopy pair. If data is being copied in the background, the

copy progress (%) is also displayed.

Table 43

General ShadowImage troubleshooting

Error

Corrective Action

SI390 operations do not function

properly.

Verify all SI390 requirements and restrictions are met.
Verify the XP128/XP1024/XP10000/XP12000 is powered on and fully

functional (NVS, cache, DFW).
Check all input values and parameters to verify that you entered the correct

information on the SI390 windows (for example, P-VOL and S-VOL IDs).

The volume pairs are not

displaying correctly.

Verify the correct CU image is selected.