Table 35, Table 36 – HP StorageWorks XP Remote Web Console Software User Manual
Page 85
ShadowImage for z/OS user guide
85
The following figure shows an example of combining ShadowImage - FlashCopy and SI390 pairs in the L1
and L2 pairs.
Figure 36
Possible combination of ShadowImage - FlashCopy and Slz and SI390 pairs
The following table shows the relationship between the L1 pair status and the availability of SI390 or
ShadowImage - FlashCopy pair operations on the associated L2 pairs.
shows the relationship
between the L2 pair status and the availability of pair operations on the associated L1 pairs.
Table 35
Relationship between L1 pair status and L2 pair operations
L1 Pair Status
L2 Pair Operations
Add
Pair
Split
Pair
Resync
Pair
Reverse Resync/
Quick Restore
Susp.
Delete
Establish
Relationship
Pending
The combination has no relationship with the ShadowImage
- FlashCopy pair. You cannot perform the operation.
OK
NO
Duplex
OK
NO
SP-Pend
OK
NO
V-Split
OK
NO
Split
OK
OK
Resync
OK
NO
Resysnc-R
OK
NO
Suspend
OK
NO
Table 36
Relationship between L2 pair status and L1 pair operations
L2 Pair Status
L1 Pair Operations
Add
Pair
Split
Pair
Resync
Pair
Reverse Resync/
Quick Restore
Susp.
Delete
Establish
Relationship
F-Copy
NO
NO
NO
NO
OK
OK
NO
- StorageWorks MSL6000 Tape Library (61 pages)
- Лент-е накопители HP StoreEver DAT (64 pages)
- Лент-е накопители HP StoreEver DAT (50 pages)
- StoreEver Ultrium Tape Drives (78 pages)
- StoreEver Ultrium Tape Drives (76 pages)
- Linear Tape File System Software (20 pages)
- StoreEver Ultrium Tape Drives (61 pages)
- StoreEver TapeAssure Software (40 pages)
- StoreEver Ultrium Tape Drives (75 pages)
- StoreEver Ultrium Tape Drives (60 pages)
- Linear Tape File System Software (28 pages)
- Linear Tape File System Software (25 pages)
- 2600fx Optical Disk Drive (65 pages)
- Ленточный автозагрузчик HP StorageWorks DAT 72x10 (58 pages)
- StorageWorks 1000 Modular Smart Array (81 pages)
- StorageWorks 1500cs Modular Smart Array (48 pages)
- StorageWorks 1500cs Modular Smart Array (52 pages)
- StorageWorks 1500cs Modular Smart Array (71 pages)
- 2000fc Modular Smart Array (150 pages)
- StorageWorks 1000 Modular Smart Array (72 pages)
- Servidor de almacenamiento HP ProLiant DL585 G2 (152 pages)
- Sistemas de almacenamiento de red HP StorageWorks X3000 (152 pages)
- Software de HP StoreVirtual VSA (127 pages)
- Software de HP StoreVirtual VSA (85 pages)
- X500 Data Vault (331 pages)
- StorageWorks 1000i Virtual Library System (122 pages)
- StorageWorks XP Remote Web Console Software (20 pages)
- 200 Storage Virtualization System (176 pages)
- XP Array Manager Software (101 pages)
- StorageWorks MSA 2.8 SAN Switch (22 pages)
- StorageWorks MSA 2.8 SAN Switch (104 pages)
- StorageWorks MSA 2.8 SAN Switch (270 pages)
- StorageWorks MSA 2.8 SAN Switch (307 pages)
- StorageWorks All-in-One SB600c Storage Blade (78 pages)
- StorageWorks All-in-One SB600c Storage Blade (60 pages)
- StorageWorks All-in-One SB600c Storage Blade (72 pages)
- StorageWorks All-in-One SB600c Storage Blade (80 pages)
- ProLiant DL585 G2 Storage-Server (150 pages)
- Data Protector Express Basic-Software (83 pages)
- Data Protector Express Basic-Software (93 pages)
- ProLiant DL185 G5 Storage Server (174 pages)
- ProLiant High Availability Storage Server (72 pages)
- StorageWorks 2000fc G2 Modular Smart Array (76 pages)
- 2000I G2-Modular-Smart-Array (48 pages)
- P2000 G3 MSA Array Systems (58 pages)