ONLINSEC
YES = Does not check path group.
NO = Checks path group.
CU number or this parameter is valid only for the DKC emulation type 2105.
For MODE (COPY), the path group for the T-VOL is checked. For Quick Restore or
Reverse Resync request is made in MODE (RESYNC), the path group for both the
primary volume (S-VOL) and target volume (T-VOL) is checked.
CSUSPEND
DEVN
Device number.
PRIM
Primary volume (S-VOL): SSID, serial number, channel connection address, CU
number (only for the DKC emulation type 2105).
You can set an additional parameter corresponding to each request instead of a
serial number. For a steady split request, the parameter is MPS00. This request is
valid for steady split. The parameter locations and descriptions are as follows:
Byte 0-6: Fixed value (xF0*7)
Byte 7: Indication of MRCF. ‘M’ = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. ‘P’ = SPLIT
Byte 9: Subcode-2. ‘S’ = Steady Split Å Requests steady split.
Byte 10-11: Not used (xF0*2)
If you set a parameter other than the above parameters, the command will be
rejected.
SEC
Secondary volume (T-VOL): SSID, serial number, channel connection address, CU
number (only for the DKC emulation type 2105).
PRIMARY
Not applicable.
QUIESCE
For information on the QUIESCE parameter, see ”
The parameter is valid only for the DKC emulation type 3390.
CDELPAIR
DEVN
Device number.
PRIM
Primary volume (S-VOL): SSID, serial number, channel connection address, CU
number (only for the DKC emulation type 2105).
Among them, the following shows the additional parameters that can be set
according to the requests made in replacement of the serial number.
For an At-Time Split Delete request, the parameter is MAnn0. The parameter
locations and descriptions are as follows:
Byte 0-6: fixed value (xF0*7)
Byte 7: Indication of MRCF. 'M' = MRCF Å Distinguishes SI390 from TC390.
Byte 8: Subcode-1. 'A' = At-Time Split Å Distinguishes at-time split from add.
Byte 9-10: Consistency group ID. 'nn' = Consistency group ID specified
hexadecimally Å Requests at-time split delete.
Byte 11: Not used (xF0)
SEC
Secondary volume (T-VOL): SSID, serial number, channel connection address, CU
number (only for the DKC emulation type 2105).
CQUERY
DEVN
Device number.
PATHS
Not applicable.
CRECOVER
CRECOVER is not used for SI390.
CGROUP
CGROUP is not used for SI390.
Table 21
TSO command parameters (continued)
Command
Parameter
Description