Deployment from hp sum, Executing hp sum – HP ProLiant Support Pack User Manual
Page 12

Introduction 12
HP SUM
version
Delivered with
Support and limitations
Servers firmware
•
No support to download the latest
components available from ftp.hp.com
through HP SUM GUI and command line
options
4.0.1
•
HP ProLiant Support Pack for Windows
8.50
•
HP ProLiant Support Pack for Linux
8.50
•
No support for BL860c/BL870c/BL890c i2
Servers firmware or HP Integrity Support
Pack
4.0.2
•
HP Smart Update DVD 9.10
•
No support for BL860c/BL870c/BL890c i2
Servers firmware or HP Integrity Support
Pack
Deployment from HP SUM
The following sections discuss deployment from HP SUM.
Executing HP SUM
HP SUM provides three modes of execution for users:
•
GUI—For firmware and software deployments
•
Express—For software deployments only (local host only)
•
Scripted—For firmware and software deployments running silently
HP SUM enables you to deploy to both local and remote deployments. HP SUM can run in both
standard Windows® and Linux operating systems in online mode and in offline mode (available on
HP Smart Update Firmware DVD) through special boot environments based on Linux boot kernels as
long as the prerequisites are met.
Use the following table to determine the correct execution mode for the server use case.
IMPORTANT:
Before deploying software updates to a target server, be sure that a recent
backup of the target server is available in the event the deployment procedure fails.
Scenario
Description
HP SUM command HP deliverable
Interactive, graphical
deployment on a local
host (Run HP SUM on
the server being
updated.)
Use this scenario when
you:
•
Are not familiar with
command line tools
•
Are deploying
components on a
local, single host
•
Do not require
scripting
•
Want to select the
components to be
installed
•
Windows®:
hpsum
•
Linux:
./hpsum
•
Online:
HP ProLiant Support Pack
for Windows® and Linux
or
Smart Update Firmware
DVD
•
Offline:
Smart Update Firmware
DVD