beautypg.com

6 preparing for version 2 operations, Requirements for version 2 – HP StorageWorks XP Remote Web Console Software User Manual

Page 63

background image

6 Preparing for Version 2 Operations

This chapter describes the requirements and preparations for performing Version 2 operations.

Page 63

Page 64

Page 70

Page 71

Page 71

Requirements for Version 2

CAUTION:

Version 1 and Version 2 cannot be used simultaneously. If one or more Version 1

relationships exist in the storage system, you cannot establish any Version 2 relationships until you
withdraw all existing Version 1 relationships.

You can establish a Version 2 relationship not only for simplex volumes, but also for ShadowImage
for Mainframe S-VOLs or T-VOLs in a status other than simplex. For information about sharing
volumes with ShadowImage for Mainframe, see

(page 54)

.

(page 63)

describes other requirements for using Version 2.

Table 37 Requirements for Version 2

Requirement

Item

I-2105 and I-2107

Controller emulation type

The controller emulation type of an S-VOL and a T-VOL
must be the same.

Version 2 can use a volume whose LDKC:CU:LDEV (LDKC:
control unit image: logical device ID) is between 00:00:00
and 00:FE:FF, and between 01:00:00 and 01:FE:FF.

Available volume

(page 63)

lists the emulation types supported by Version 2 and the conditions for the combination

of S-VOL and the T-VOL.

Table 38 Emulation Types Supported by Version 2

Emulation Type of T-VOL

Emulation Type of S-VOL

3390-M

3390-L

3390-9

3390-3

3380-3

NG

NG

NG

NG

Yes

3380-3

Yes

Yes

Yes

Yes

NG

3390-3

Yes

Yes

Yes

Yes

NG

3390-9

Yes

Yes

Yes

Yes

NG

3390-L

Yes

Yes

Yes

Yes

NG

3390-M

If the emulation type starts with 3390, you can specify volumes with different emulation types for
the S-VOL and the T-VOL. However, you cannot establish a relationship using a 3380-3 volume
and a volume whose emulation type starts with 3390. In the case of a 3380-3 volume, you must
specify 3380-3 volumes for both the S-VOL and the T-VOL.

The specified extent must be within the range of the user cylinders in each volume.

Requirements for Version 2

63