Table 66 Parameters for the ICKDSF Command (in Version 2) (continued)
Description
Value
Parameter
Command
OS of the host server is
MVS, this parameter or the
UNITADDRESS parameter is
required.
Sets the SYSNAME in the
ASSGN system control
SYSNAME
SYSNAME
statement. If the OS of the
host server is VSE, this
parameter is required.
Specifies the device number
(device address) of the
Source device number
UNITADDRESS, UNITADDR,
or UNIT
S-VOL on which you want to
perform the FLASHCPY
QUERY
command. If the OS
of the host server is MVS,
this parameter or the
DDNAME parameter is
required.
Displaying Information on Version 2 Pairs: FLASHCPY QUERY
To see the information about the Version 2 pair, execute the ICKDSF FLASHCPY QUERY command.
See
Figure 87 FLASHCPY QUERY Command Execution
FLASHCPY QUERY UNIT(X'7000')
shows an example of information displayed as a result of executing the FLASHCPY
QUERY
command.
Figure 88 FLASHCPY QUERY Command Execution Result
FLASHCOPY VOLUME CAPABILITY INFORMATION TABLE
MAXIMUM MAXIMUM
EXISTING ALLOWED RELATIONS
RELATIONS RELATIONS EXCEEDED CAPABILITY
--------- --------- --------- ----------
1 1000 NO SRC CAP
TGT CAP
CAPABILITY LEGEND
ASY PVOL = ASYCHRONOUS PPRC REMOTE COPY PRIMARY
CC SRC = CONCURENT COPY SOURCE
INACCESS = VOLUME INACCESSIBLE, DATA NOT OBTAINABLE
INHIBIT = FLASHCOPY INHIBITED O. THIS VOLUME
MAX EXCD = MAXIMUM RELATIONS EXCEEDED AT VOLUME OR ESS LEVEL
NEITHER = VOLUME NEITHER FC SOURCE NOR FC TARGET CAPABLE
PPRC PRI = PPRC PRIMARY
PPRC SEC = PPRC SECONDARY
PHASE 1 = PHASE 1 (VERSION 1) RELATIONSHIP EXISTS O. VOLUME
SRC CAP = FLASHCOPY SOURCE CAPABLE
TGT CAP = FLASHCOPY TARGET CAPABLE
XRC SRC = XRC SOURCE
describes the meaning of information displayed as a result of executing the FLASHCPY
QUERY
command.
128