Enww configure device menu 39 – HP Color LaserJet CP3520 Printer Series User Manual
Page 51
Item
Sub-item
Sub-item
Values
Description
SELECT ALL
TESTS
YES
NO*
Use this item to select all available embedded
tests.
Select YES to choose all tests. Select NO to
select individual tests.
EXECUTION TIME
[M]
Use this item to specify the length of time (in
minutes) that an embedded test will be run.
You can select a value from 0 to 24 minutes.
If you select zero (0), the test runs indefinitely
until an error occurs or the product is turned
off.
Data gathered from the HTTP, SNMP, and
Data Path tests is printed after the tests have
completed.
EXECUTE
YES
NO*
NO: Do not initiate the selected tests.
YES: Initiate the selected tests.
PING TEST
This test is used to check network
communications. This test sends link-level
packets to a remote network host, then waits
for an appropriate response. To run a ping
test, set the following items:
DEST TYPE
IPV4
IPV6
Specify whether the target product is an IPv4
or IPv6 node.
DEST IPV4
Type the IPv4 address.
DEST IPV6
Type the IPv6 address.
PACKET SIZE
Specify the size of each packet, in bytes, to
be sent to the remote host. The minimum is
64 (default) and the maximum is 2048.
TIMEOUT
Specify the length of time, in seconds, to wait
for a response from the remote host. The
default is 1 and the maximum is 100.
COUNT
Specify the number of ping test packets to
send for this test. Select a value from 0 to 100.
The default is 4. To configure the test to run
continuously, select 0.
PRINT RESULTS
YES
NO*
If the ping test was not set for continuous
operation, you can choose to print the test
results. Select YES to print results. If you
select NO, results are not printed.
EXECUTE
YES
NO*
Specify whether to initiate the ping test.
Select YES to initiate the test, or NO to not
run the test.
PING RESULTS
Use this item to view the ping test status and
results using the control panel display. You
can select the following items:
PACKETS SENT
Shows the number of packets (0 - 65535)
sent to the remote host since the most recent
test was initiated or completed. The default is
0.
Table 2-1
Embedded Jetdirect and EIO
ENWW
Configure device menu
39