beautypg.com

HP Insight Management-Software User Manual

Page 74

background image

6.

Replace the blade server FC HBA mezzanine cards with FlexFabric Adapter mezzanine cards.

7.

Unassign any FC profile connections that are attached to the interconnect bays being replaced.
This can be done by unassigning the FC connections in the server profile. HP recommends
that you do this in order so you do not lose the WWN addresses.

8.

Delete any FC SAN fabric connections that were created using uplinks from the interconnect
bays that are to be replaced.

9.

Remove the existing modules that are not FlexFabric from both horizontally adjacent bays
three to eight.

10. Add the two existing VC modules in both horizontally adjacent bays three and four with

appropriate FC SFP+ transceivers.

11. Create new networks with FC SAN fabrics linked to the new FlexFabric module uplink ports.
12. Reassign the Ethernet connections in server profiles or add new connections to the server

profiles, depending on what was selected in

Step 4

and

Step 7

.

13. Save the configuration again.

IMPORTANT:

HP recommends that you save the configuration so that if there is a problem

with the VC firmware upgrade you can restore the system to the last configuration snapshot.

14. Remove the Ethernet modules from bays one and two.
15. Add the two existing VC Ethernet modules in both horizontally adjacent bays one and two.
16. Follow the Virtual Connect Domain Setup Wizard, and select the option to restore the domain

for the saved configuration file in

“Replacing VC Ethernet and FC modules with FlexFabric

modules in an existing VCEM managed VC Domain” (page 73)

.

After performing all the steps in

“Replacing VC Ethernet and FC modules with FlexFabric modules

in an existing VCEM managed VC Domain” (page 73)

you can create, or edit any existing server

profiles and use the available networks or SAN Fabrics from the FlexFabric module to create iSCSI
connections.

Upgrading to an HP Virtual Connect 8 Gb, 24-port FC module or an HP VC 8 Gb
20-port FC module

Upgrading to an HP Virtual Connect 8 Gb 24-port FC module or an HP VC 8 GB FC module in a
VC Domain managed by VCEM requires performing several important steps in both VC Manager
and VCEM depending on the starting configuration.

To replace a VC FC module with a different type of module in a VCEM managed VC Domain:
1.

Click the VC Domains tab from the VCEM home page.

2.

Select the VC Domain containing the VC modules to be replaced.

3.

Click Remove from VC Domain Group. Wait for the job to complete successfully.

4.

Follow the steps described in the HP Virtual Connect for c-Class BladeSystem User Guide at

http://h18004.www1.hp.com/products/blades/components/c-class-tech-installing.html

for

your specific replacement scenario, The following replacement modules are examples of the
current replacement scenarios:

Replacing an HP 4Gb VC-FC Module, HP VC 4Gb FC Module, or HP 8Gb 20-Port FC
Module with an HP VC 8Gb 24-Port FC Module

Replacing an HP 4Gb VC-FC Module or HP VC 4Gb FC Module with an HP VC 8Gb
20-Port FC Module.

Replacing an HP 8Gb 24-Port FC Module with an HP VC 8Gb 20 Port FC Module

IMPORTANT:

After installing the new VC FC modules, omit any VC steps to recreate FC

connections. You must use VCEM to recreate and reassign server profile connections.

5.

Click the VC Domains tab from the VCEM home page.

74