13 Troubleshooting VCEM

When you are upgrading to a new and different CMS, or are moving to a 64-bit CMS, you might
need to migrate your data by using the Systems Insight Manager data migration tool. If you are
upgrading to a new version of VCEM on the same CMS, data migration with the Systems Insight
Manager data migration tool is not necessary. For more information, see the Data Migration of
an Existing Microsoft Windows CMS to a new Insight Management 7.2 system white paper
on
the Systems Insight Manager Information Library at

http://www.hp.com/go/insightmanagement/

docs

.

Using iSCSI boot configuration with IE10 in compatibility view

The iSCSI boot configuration web GUI is not supported in IE10 compatibility view. Use IE10 without
compatibility view to make changes to the iSCSI boot configuration.

Cannot resynchronize VC Domain that has a configuration mismatch state
due to an enabled VC feature

If VCEM failed to resynchronize a VC Domain that is in a configuration mismatch state because
there are one or more VC features enabled (see

Figure 87

) you will need to perform the following

steps to correct the VC Domain:

Figure 87 Configuration mismatch details

1.

Telnet into VCM using an SSH connection such as SSH
[email protected]

, where xxx is the VC Domain IP address to access

the VCM CLI.

2.

Enter show external-manager at the VCM command prompt to determine the user name
of the external manager account. For this example, assume that the user name that is returned
is xyz.

154 Troubleshooting VCEM