Displaying converged uplink sets and fcoe networks, Viewing lacp timer attributes for vc domains – HP Insight Management-Software User Manual
Page 67
Figure 37 FCoE allocated port speed example
You can also view or select a new value for the FCoE connections table preferred port speed on
the edit server profile page.
displays an example of preferred port speed (default port
speed when adding a new connection) in the FCoE connections table.
Figure 38 FCoE preferred port speed example
Displaying Converged Uplink sets and FCoE networks
displays Converged Uplink Sets and FCoE networks in the VC Domain details.
Figure 39 VC Domain details for Converged Uplink sets and FCoE networks
Viewing LACP timer attributes for VC Domains
VCM offers you the option of configuring the timeout for LACP which changes the frequency of
control messages (LACPDU). The feature can be either a short duration (1 second) or a long duration
(30 seconds). VCEM displays that information in the VC Domain network details.
displays
VC Domain network details with the LACP timer attribute.
VC Domain Maintenance
67