Ldev capacity, External lu's maximum usable capacity – HP StorageWorks XP Remote Web Console Software User Manual
Page 180
•
Each emulation type has its own maximum usable capacity.
shows the external LU's
maximum usable capacity for each emulation type.
Table 32 External LU's maximum usable capacity
External LU's maximum usable capacity
Emulation type
2 TB
OPEN-V
575.98 GB
OPEN emulation type other than OPEN-V
575.98 GB
3380 mainframe emulation type
695.98 GB
3390 mainframe emulation type
According to these restrictions, you can determine the external LU's maximum usable capacity for
each emulation type. When the mapped external LU's capacity is more than the maximum capacity
of the specified emulation type, a certain part of the external LU cannot be used.
shows the relationship of the minimum LDEV capacity, base LDEV capacity, minimum data
area capacity, base data area capacity, and control information area capacity.
Figure 70 LDEV capacity
.
shows how to determine the volume capacity using the example of the OPEN-3 case.
Required volume capacity for emulation types
180