HP StorageWorks XP Remote Web Console Software User Manual
Page 153
Corrective action
Error
Status: The reply of the external array was ABORTEDCOMMAND. An
error might have occurred on the external array side.
Corrective action: The port of the external array is recognized. Check
the external array's setting and the condition of the connection to the
external array (for example, cables or switches). If you cannot restore
the path, contact your HP account support representative.
Command aborted
Status: The external array's status is BUSY.
Corrective action: The external array's port is still recognized. Check
the external array's settings and the load on the external array (for
example, check whether the configuration assigns too much load on
the external array). If you cannot restore the path, contact your
HP account support representative.
Busy
Status: The external array's status is Reserved. You cannot access the
external array's device from the local array.
Corrective action: Remove the Reserve status on the external array's
device.
LDEV reserved
Status: The external array's status is Blocked due to an abnormal reply
(Response). You might not be able to access the external array's device,
or data protection might be set on the external array's device.
Corrective action: The external array's port is recognized. Check the
external array's setting and status. If you cannot restore the path,
contact your HP account support representative.
Response error
Status: The external array (for example, XP) port attribute changed to
Initiator.
Corrective action: Set the external array's port attribute back to target.
If you cannot restore the path, contact your HP account support
representative.
Initiator port
Status: The port attribute of the external array changed to RCU target.
Corrective action: Set the port attribute of the external array to Target.
If you cannot restore the path, contact your HP account support
representative.
RCU target port
Status: The external array's port attribute is unknown.
Corrective action: The external array's port is recognized. Check the
condition of the connection (for example, cables and switches) to the
external array. If you cannot restore the path, contact your HP account
support representative.
Unknown port
XP External Storage Software User Guide
153