Execution results – HP XP20000XP24000 Disk Array User Manual
Page 130
Table 34 Parameters of the SerialNumber Tag
Number of Characters
Range of Values
Setting
Parameter
Column in the
Spreadsheet
5 or fewer decimal
digits
00000 to 99999
Serial number of the
storage system
SerialNumber
A
Execution Results
The execution results of the CFL Extension commands are exported to the following area in the
output file:
•
After the semicolon on each row
•
The row below the row where an error occurred
describes the exported contents.
Table 35 Exported Contents of the Execution Results
Exported Content
Description
Row
Normal end: Finished normally.
Warning(xxxx-yyyyy): Errors occurred on some rows.
Error(xxxx-yyyyy): Errors occurred on every row.
Indicates the overall result of the
spreadsheet.
Declaration
For the CFLCHK command:
•
Check OK: Finished normally.
•
Check NG(xxxx-yyyyy): An error occurred on this row.
For the CFLGET or CFLSET command:
•
Normal end: Finished normally.
•
Error(xxxx-yyyyy): An error occurred on this row.
Indicates the result of the line with a
parameter.
Parameter
(xxxx-yyyyy) indicates part codes and error codes. For details about these codes, see the HP
StorageWorks XP24000/XP20000 Remote Web Console Error Codes.
Examples of execution results are as follows:
•
Case 1: An operation tag has an error.
The following example shows execution results when an operation tag has an error. To identify
where an error occurred, find the row above the row that begins with the #^ characters. In
this example, an error occurred in the SuspendPair tag.
#!Version 05_02_01,CFL_RemoteCopyJournalMF,PairOperation,;Error(6505-66004)
[SerialNumber]
64040,;Check OK
[Suspend-Pair]
#^,;Check NG(6505-66004)
00,04,40,01,P-VOL,00,64040,Group,Disable,Flush,;
•
Case 2: A parameter has an error.
The following example shows execution results when a parameter has an error. To identify
where an error occurred, find all the rows that display an error after the semicolon. In this
example, errors occurred on the first and fourth row in the SuspendPair tag.
#!Version 05_02_01,CFL_RemoteCopyJournalMF,PairOperation,;Warning(1305-66578)
[SerialNumber]
64040,;Normal end
[SuspendPair]
00,04,40,01,P-VOL,00,64041,Volume,Disable,Flush,;Error(6505-58075)
00,04,41,01,P-VOL,00,64040,Volume,Disable,Flush,;Normal end
130 Using the CFL Extension