beautypg.com

Figure 1-2, Remote mirroring after a switchover – HP NonStop G-Series User Manual

Page 20

background image

ServerNet Nomadic Disk Overview

ServerNet Nomadic Disk User’s Guide425485-001

1 -4

Data Paths and Disk Drive Ownership After a

Switchover

Data Paths and Disk Drive Ownership After a Switchover

To manage outages, both the primary disk drives and remotely located mirror disk drives
can be switched to the backup node. When a outage brings down the primary node, the
ownership of the disk drives can be switched to \BCK. After a switchover, the active
data paths are as shown in

Figure 1-2

.

The thick solid lines designate active data paths, which are between the backup node
and the primary and mirror disk drives. The primary disk drives, which are located
with the primary node \PRI, are now owned by the backup node \BCK. The mirror
disk drives are also now owned by the backup node.

The thinner lines indicate inactive data paths, which are between the primary node
and the primary and mirror disk drives.

Figure 1-2. Remote Mirroring After a Switchover

Primary Node

\PRI

MSEB

MSEB

SNDA

SNDA

Processor
Enclosure

MSEB

MSEB

SNDA

SNDA

Processor
Enclosure

SNDA

SNDA

\PRI I/O

Enclosure

IOMF 2

IOMF 2

SNDA

SNDA

\BCK I/O

Enclosure

IOMF 2

IOMF 2

Switch

Module

1

2

3

4

1

2

3

4

Mirror

Disks

Backup Node

\BCK

1

2

3

4

Switch

Module

1

2

3

4

Primary

Disks

VST101.vsd