HP StorageWorks 1200r All-in-One Storage System User Manual

Page 128

background image

Solution

Possible cause

Description

Alert text

Object

Health should return to
normal. You can use the
tools available with the HP
Array Configuration Utility
to view any logs that may
explain what caused this
problem.

This logical disk is
currently rebuilding.
During this time you
may notice a
performance
degradation.

Health:
Resyncing
mirrors or
rebuilding
parity.

Only SWSM version
5.0.2 or later is
supported.

An
incompatible
version of HP
StorageWorks
Storage
Mirroring is
installed on
this server.

Replication

Update the credentials
using the Application
Credentials dialog box.
The credentials must be
those of a user in the local
DoubleTake Admin
Group. See “

Configure

Application
Credentials

” on page 65

for more information.

The credentials for a
user in the DoubleTake
Admin Group have
not been entered
using the Application
Credentials dialog
box.

Could not get
replication
license state.
Check
replication
credentials
and for valid
license key.

Reinstall StorageWorks
Storage Mirroring and
verify that the Storage
Mirroring service is
running.

Replication is
not installed
properly or the
Storage
Mirroring
service is not
running.

Refer to
ASMServerLog.txt

for

more details.

Replication
discovery
failed.

Verify that SWSM version
5.0.2 or above is installed
and properly licensed.

Replication sets exist
in StorageWorks
Storage Mirroring but
ASM cannot use
SWSM.

Host has
replication sets
but no
replication
capability.

Verify that SWSM version
5.0.2 or above is installed
and properly licensed.

Replication sets exist
in StorageWorks
Storage Mirroring but
ASM cannot use
SWSM.

Host has
replication
sets, but
replication
capability is
unusable.

Refer to the StorageWorks
Storage Mirroring
documentation for more
information.

The replication source
has run out of kernel
memory.

Out of
memory.

Troubleshooting, servicing, and maintenance