Saving configuration changes – HP Storage Mirroring V5 Software User Manual
Page 39
HP StorageWorks Storage Mirroring Application Manager user’s guide
29
•
Create Connection
—
(Default = Selected)
Application Manager will create the appropriate connection
between the source and target using the automatically-generated replication set. This should only be
disabled if you would like to verify the replication set that is created by Application Manager prior to
connection.
•
Create Failover Monitor
—
(Default = Selected)
Application Manager will create a failover monitor on the
target to monitor the source for failure. This monitor will use the failover parameters specified during
configuration, as well as the script files that have been created.
Saving configuration changes
After you have changed the configuration parameters, click
OK
to apply the settings. If you click
Cancel
, any
changes you have made will be discarded and the previous configuration parameters will be used.
When you have finished configuring the optional protection options, continue with ”
NOTE:
If you close the Storage Mirroring Application Manager prior to enabling protection, your changes
will not be saved. You
must
enable protection in order to save your configuration settings for a source/target
pair.