Scripted deployment 66
Linux smart component return codes
Single target servers:
Error level Meaning
0
The smart component installed successfully.
1
The smart component installed successfully, but the system must be restarted.
2
The installation was not attempted because the required hardware is not present, the
software is current, or there is nothing to install.
3
The smart component failed to install. For more details, see the log file.
Multi-target servers:
Error level Meaning
0
The installation of the deliverable is successful. No reboot is required.
1
The installation of the deliverable is successful. Reboot is required for the deliverable to be
enabled.
2
The installation was not attempted because the version to be installed matches the version
already installed.
3
The installation was not attempted because of one of the following:
•
The version to be installed is older than the version already installed.
•
The supported hardware is not present, not enabled, or in a state that an installation
could not be attempted.
•
The smart component does not support the environment.
•
There is nothing for the component to accomplish.
4
If the component is installing to a remote target, such as Onboard Administrator or other
network-based deployment, this return code indicates that the target cannot be found.
5
The installation was canceled by a user before anything could be installed.
6
The installer cannot execute because of an unmet dependency or installation tool failure.
7
The actual installation operation (not the installation tool) failed.
Linux RPM return codes
Error level Meaning
0
The Linux RPM installation was successful.
1
The Linux RPM installation failed.
Input files
HP SUM provides the ability to script the update of multiple, individual targets or groups of targets within
a single operation through the input file functionality. To protect your credentials, use a secure server or a
management console.
To create an input file, use Microsoft® Notepad. All section headers and trailers [END] must match.
Failure to use the SILENT=YES option causes the GUI mode to be used, but the information provided
enables you to skip screens where information has already been provided. The DRYRUN=YES option can