Mapping multiple external lus at (add lu (auto)) – HP XP External Storage Software User Manual
Page 97
15.
Click OK. The mapping set in the Add LU window is applied to the local array, and the specified
contents appear in the Device list.
If errors occur during the external LU mapping operation, failed settings and error codes appear
in the Preset list. To check error messages, right-click the failed setting, and select Detail.
Mapping multiple external LUs at (Add LU (Auto))
This section describes the procedure to map multiple external LUs at one time. The procedure starts
with the Add LU (AUTO) command.
NOTE:
Before mapping the external LU, you must check whether any application (for example, RAID Manager
XP) using the command device is in progress. If any application using the command device is in progress,
stop the application.
When mapping multiple external LUs at one time, the CU:LDEV numbers for the mapped destination
internal LDEVs are assigned in a series. When performing the mapping operation, you can select the
first CU:LDEV number for the mapped destination internal LDEVs. External Storage XP assigns the
selected CU:LDEV number as the first mapped destination LDEV, and as many subsequent CU:LDEV
numbers are kept for mapping as the number external LUs required to be mapped. To automatically
perform the mapping operation, you can let External Storage XP select the first CU:LDEV number.
NOTE:
If you set
Interval for the mapping, the CU:LDEV number of the internal LDEV that must be mapped is set
to the specified interval value.
CAUTION:
If the LUs you are mapping include a volume with the VMA setting, you cannot use the
Add LU (AUTO)
command to map them at one time.
Use the Auto Map Setting and Select LDEV windows (
) for mapping multiple external LUs
at one time.
External Storage XP user guide for the XP12000, XP10000, SVS200