Chapter 7 Establishing Switch Access

Avaya P334T-ML User’s Guide

35

6

At the prompt, type reset and press Enter to reset the stack. After the Reset,
log in again as described above.

7

At the prompt, type set ip route and replace
and with the destination and gateway IP addresses.

Establishing a Telnet Connection

Perform the following steps to establish a Telnet connection to the Avaya P330 for
configuration of Stack or Router parameters. You can Telnet the Stack Master
IP address:
1

Connect your station to the network.

2

Verify that you can communicate with the Avaya P330 using Ping to the IP of
the Avaya P330. If there is no response using Ping, check the IP address and
default gateway of both the Avaya P330 and the station.

L The Avaya P330 default IP address is 149.49.32.134 and the default subnet mask

is 255.255.255.0.

3

From the Microsoft Windows taskbar of your PC click Start and then Run (or
from the DOS prompt of your PC), then start the Telnet session by typing:
telnet

If the IP Address in the Telnet command is the IP address of the stack, then
connection is established with the Switch CLI entity of the Master module.
When you see the “Welcome to P330” menu and are prompted for a Login
Name, enter the default name root

4

When you are prompted for a password, enter the User Level password root
in lower case letters (do NOT use uppercase letters). The User level prompt will
appear when you have established communications with the Avaya P330.

5

Press Enter to save the destination and gateway IP addresses.

Establishing an SSH Connection

Perform the following steps to establish an SSH connection to the Avaya P330 for
configuration of Stack or Router parameters. You can open an SSH session to the
Stack Master IP address:
1

Connect your station to the network.

2

Verify that you can communicate with the Avaya P330 using Ping to the IP of
the Avaya P330. If there is no response using Ping, check the IP address and
default gateway of both the Avaya P330 and the station.

L The Avaya P330 default IP address is 149.49.32.134 and the default subnet mask

is 255.255.255.0.

3

Using the show ip ssh command, ensure that an SSH key has been generated
on the switch using the crypto key generate dsa command and that SSH
is enabled on the switch using the ip ssh enable command.

4

Using your SSH client software, open a session to the Stack Master IP address.