beautypg.com

Settings (p. 5-14) – Canon VB-M700F User Manual

Page 58

background image

5

-14

General Upload

[Upload]

Select [Upload Disabled], [HTTP Upload] or [FTP

Upload] for the upload method.

Note

To lower the upload or e-mail notification load, try the following
measures. Also check the settings including the network to the
server.

• Reduce the image file size:

– Set a lower value under [Image Quality] for JPEG (P. 5-12).
– Set a lower value for [Image Size: Upload] for JPEG

(P. 5-12).

• Reduce the uploading frequency:

– Reduce the value in [Pre-event Buffer (number of image

frames)] or [Post-event Buffer (number of image frames)]
(P. 5-19).

– If [Volume Detection Event] is enabled, disable [ON Event

Operation] or [OFF Event Operation] (P. 5-19).

– From the Intelligent Function Setting Tool [Event] tab >

disable [ON Event Operation], [OFF Event Operation] or
[Detected mode Operation] (P. 6-12).

– If [External Device Input Event] is enabled, disable [ON

Event Operation] or [OFF Event Operation] (P. 5-20).

– If [Timer Event Setting] is enabled, increase the value in

[Repeat Interval] (P. 5-20).

HTTP Upload

1

[Notification]

Select [Notification Only with HTTP] or [Image attached

Notification with HTTP] as the content of notification.

2

[URI]
Enter the URI to be uploaded to (using up to 255

characters).

3

[User Name], [Password]
Enter the user name and password required for

authentication.

The authentication method is BASIC authentication.

4

[Proxy Server]
Enter the host name or IP address of the proxy server

(using up to 63 characters).

5

[Proxy Port]
Enter the port number of the proxy server (factory

default setting is [80]).

6

[Proxy User Name], [Proxy Password]

Enter the user name and password of the proxy server.

The authentication method is BASIC authentication.

7

[Parameter (query string)]
Enter the parameter (using up to 127 characters).

Parameters can be specified using the “%” character

(P. 8-4).

8

[HTTP Upload Test]

Clicking [Exec] initiates an upload test based on the

settings currently entered. It is not necessary to click

[Apply].

[Upload]
Setting HTTP/FTP Upload and E-mail Notification

The following can be set here.

• General Upload

Set the upload operation to be performed.

• HTTP Upload

Set HTTP connection uploads.

• FTP Upload

Set FTP connection uploads.

• E-mail Notification

Set event information and image e-mail

notifications.

Important

• If the upload function is used, either the [Event] menu must

be set (P. 5-19) or the [Event] tab in the Intelligent Function
Setting Tool (P. 6-10) must be set.

• If you are using both e-mail notification by text and image

upload by HTTP/FTP, set [Image Size: Upload] (P. 5-12) to
[320 x 240] or less.

• HTTP upload does not support SSL/TLS.

• If the camera is set to perform upload or e-mail notification

continuously, not all images or e-mails may be sent
depending on the image size and the network condition to
the server. In this case, an event log message is displayed
(P. 5-32).

• If the destination for HTTP/FTP upload or e-mail notification is

set for a Windows operating system, IPsec communication
cannot be applied.

This manual is related to the following products: