beautypg.com

Canon VB-M700F User Manual

Page 129

background image

List of Log Messages

8

-19

8

Appen

dix

S412 Timer service initialization error [crit]

S413 Timer service runtime error [crit]

S501 Fan stop detected [alert]

S502 Temperature fuse disconnect detected [alert]

Description

timer initialization error [%1] [%2] (S412)

%1

Error number

%2

Cause of error

Meaning

An error occurred in the initialization of the timer service.

Countermeasure

If the problem persists after rebooting, the camera is faulty. Arrange for servicing.

Description

timer working error [%1] (S413)

%1

Error number

Meaning

An error occurred while the timer service was running.

Countermeasure

If the problem persists after rebooting, the camera is faulty. Arrange for servicing.

Description

FAN rotation speed is less than 150rpm. (S501)

Meaning

The camera's internal fan has stopped or RPM has dropped significantly.

Countermeasure

Camera needs to be serviced.

Description

Heater unit error. Fuse is cut off. (S502)

Meaning

The temperature fuse on the heater substrate was disconnected.

Countermeasure

Camera needs to be serviced.

VB-M600VE

VB-M600VE

This manual is related to the following products: