S412 Timer service initialization error [crit]
S413 Timer service runtime error [crit]
S501 Fan stop detected [alert]
S502 Temperature fuse disconnect detected [alert]
Description
timer initialization error [%1] [%2] (S412)
%1
Error number
%2
Cause of error
Meaning
An error occurred in the initialization of the timer service.
Countermeasure
If the problem persists after rebooting, the camera is faulty. Arrange for servicing.
Description
timer working error [%1] (S413)
%1
Error number
Meaning
An error occurred while the timer service was running.
Countermeasure
If the problem persists after rebooting, the camera is faulty. Arrange for servicing.
Description
FAN rotation speed is less than 150rpm. (S501)
Meaning
The camera's internal fan has stopped or RPM has dropped significantly.
Countermeasure
Camera needs to be serviced.
Description
Heater unit error. Fuse is cut off. (S502)
Meaning
The temperature fuse on the heater substrate was disconnected.
Countermeasure
Camera needs to be serviced.